Support Area-0 point-to-point lighting addresses (A=0, PL=1–15) assigned by Home + Project #684

Closed

Description

@GreenGrassBlueOcean

Problem Description

Installations configured using Legrand's Home + Project app (e.g. paired with an F460 or MyHomeServer1) assign light point addresses progressively starting at A=0, PL=1, A=0, PL=2, etc. Legrand support confirms this allocation rule cannot be changed.

When interfacing such an installation through an OpenWebNet gateway (observed on physical MH200 firmware 2.1.0, reported by @peterbeepping in OpenWebNet-HA/own-firmware-oracle#35):

  1. Discovery Rejection as Broadcast:

    • When an Area-0 actuator (such as an F411/4 channel 1 at A:0 PL:2) operates or reports status, the gateway emits *1*1*2## (single-digit WHERE 2).
    • In custom_components/myhome/light.py, build() explicitly drops single-digit WHEREs:
      if where in ("0", "00", "1", "2", "3", "4", "5", "6", "7", "8", "9", "100"):
          LOGGER.warning(
              "Refusing to create a light entity for broadcast WHERE %s (must be group or point-to-point)",
              where,
          )
          return None
      This leaves newly added Area-0 devices completely undiscoverable in Home Assistant.
  2. APL Command / Status Query Rejection:

    • In custom_components/myhome/const.py, is_apl_address() classifies 0001–0015 as canonical 4-digit APL for Area 0.
    • However, physical MH200 gateways NACK both 4-digit *1*1*0002## and 2-digit *1*1*02##.
    • Polling status with *#1*0002## or *#1*02## is likewise NACKed.
  3. Collision with Area Commands:

    • If configured as where: "2", sending *1*1*2## acts as an Area 2 command and switches all lights in Area 2 instead of the target device.
  4. Local Bus & DALI Channels:

    • F429 DALI channels assigned to A:0 PL:2–9 on local bus #4#01 (*1*1*0002#4#01## vs *1*1*2#4#01##) require verified address routing.

Proposed Plan

  1. Gather Authentic On-Wire Hardware Captures:
    • Capture live bus traces from an installation containing Area-0 devices (MH200, F460, F411/4, F429) to determine how the physical gateway, wall switches, and Home + Project app communicate.
  2. Oracle Cross-Firmware Verification:
    • Add area0.cases to own-firmware-oracle to determine which gateways (F460, MyHomeServer1, F454, MH200N) accept 0001–0015 vs 02 vs 2.
    • Also request the original MH200 CD-ROM firmware to emulate the physical MH200 directly.
  3. Gateway Profile & Disambiguation in MyHOME:
    • Allow YAML-configured Area-0 entities where the user explicitly defines the device as point-to-point.
    • For gateways that accept 4-digit addressing (F460 / MyHomeServer1), preserve 0001–0015.
    • For gateways that emit single digits (MH200), establish whether command translation or specific framing is required.

Related

Activity

  1. wave68runner commented on Oct 10, 2026

    @wave68runner

    I could be wrong, but I don't have any problem with the addresses created by Home + Project.

    Image

    Discovered with MH200 and MHS1

  2. GreenGrassBlueOcean commented on Oct 10, 2026

    @GreenGrassBlueOcean
    ContributorAuthor

    @wave68runner how is the b15 experience sofar are you happy?

  3. peterbeepping commented on Oct 11, 2026

    @peterbeepping

    Thanks for the quick and detailed reply. I ran controlled captures on the real hardware. Setup: one event session (*99*1##) and one command session (*99*0##) open at the same time, frames sent one by one, all traffic timestamped. The target point was switched physically on the actuator before each run, so its state was known.

    Hardware

    Device Model reply Firmware
    MH200 (OWN gateway, 192.168.1.x:20000) #13**154## #13**16212## = 2.1.2 (web page: service pack MH200_2_1_2.fwz, dated 30/07/2008)
    F460 (Home + Project / Home + Control server) #13**15200## 2.0.18
    Target point F411/4, output 1, configured by Home + Project as A=0 PL=2, private riser  

    The point is rendered as 2 in both cases. With the physical press only, every point of area 2 reports its state right afterwards, without switching, as if a *#1*2## had been issued. This was reproduced on all four presses. No client sent anything during the capture. From the event session alone I can't tell which device issues that implicit area-2 query: the MH200, the F460, or the actuators themselves reacting to the frame.

    My working hypothesis is that the MH200 misreads the spontaneous state report of A0PL2 as "area 2 changed" and refreshes its state cache with an area-2 status query. With a commanded change it has already seen the command, so it doesn't need to query. I plan to confirm this with two tests: physically switching an ordinary point (e.g. 21), where I'd expect no burst, and repeating the A0PL2 press with the F460 disconnected from the bus. Does your knowledge of the SCS framing explain why a local state change of an A=0 point triggers an area-status cycle, while a commanded change does not?

    Result 3: F460 as OWN gateway

    HMAC-SHA256 (*98*2##) authentication succeeds. *#13**15## and *#13**16## are ACKed. Every WHO 1 and WHO 2 frame (status and command) is NACKed, including frames for ordinary points such as *#1*12##, which the MH200 answers normally. This looks like a WHO filter rather than an addressing issue. Is this known or emulated in the F460-family profiles?

    Other observations that may be useful for emulation

    1. Status request timing. *#1*2## and *#1*0## are ACKed only about 6 s after the last real reply. During that window the MH200 forwards all bus frames into the command session, including unrelated ones (*1*19*29##, *1*2*97#4#01##). Clients have to filter.
    2. WHAT 19. Dimmer 29 emits *1*19*29## plus *#1001*29*11*111111111111111111101111## about once per second, unprompted. On a general status, six more actuators reply WHAT 19 with a *#1001 bitmask: 39, 49, 59, 89, 95#4#01 and 98#4#01. For example, 59 replies 111110111111111101100111 and 39 replies 111110111111111111100111. Is WHAT 19 strictly a fault, or could it also mean something like "no load" or "configuration"?
    3. Session limit. After a handful of open/close cycles, port 20000 first resets connections before the greeting, then refuses them outright. HTTP stays up. It recovers by itself after about 7 minutes.

    Current workarounds (for context, neither is satisfactory)

    1. Google Assistant route. Home + Control is linked to Google Home. Home Assistant sends a text command ("turn on <name>") through the Google Assistant SDK, and the F460 executes it. This works for every area-0 object, including the DALI channels and the A=00 PL10 dimmer, because the F460 addresses them correctly. The state is read back from the bus via the MH200, where the target shows up as *1*x*2##. The drawbacks:
      • it depends on the cloud, with a delay of a few seconds;
      • commands are occasionally lost, so I'm wrapping it in a verify-and-retry loop that checks the bus state after 3, 6 and 10 s and resends if needed;
      • the readback is only unambiguous because no genuine area-2 command is ever sent.
    2. Readdressing with MyHOME_Suite. Changing the point to an ordinary address (A=7 PL=1, 71) with MyHOME_Suite works immediately through OWN: *#1*71## replies *1*0*71##, and commands work. But Home + Control and Home + Project can then no longer control the object. As soon as the object is edited in Home + Project, the address is reset to A=0 PL=2. Home + Project assigns addresses itself, starting at A0PL1, and Legrand confirmed this cannot be changed. So this only works if you give up Home + Project / Home + Control for that object, which isn't an option alongside the F460.

    Questions

    1. Based on your emulations, an MH200N or F454 accept 0n/000n on input for A=0 points and A=00 PL10–15, on both the private riser and the local bus #4#01? Replacing the gateway may solve

      the problem.

    2. Any insight into the F460 NACKing WHO 1/2?
    3. Why does a local press on an A=0 point trigger an area-2 status burst (Result 2)?

    Full logs are attached. Happy to run further frames on this hardware.

    own_capture_verwarming_20261010_161733.txt
    own_capture_verwarming_20261010_161043.txt
    own_capture_luister_20261011_175623nfysieke knog.txt
    own_capture_luister_20261011_175140 homecontrol.txt

  4. GreenGrassBlueOcean commented on Oct 13, 2026

    @GreenGrassBlueOcean
    ContributorAuthor

    @peterbeepping thanks, this capture is very useful. I checked it against the firmware oracle (OpenWebNet-HA/own-firmware-oracle, suite lights-area0) and went through your three questions.

    1. Will an MH200N / F454 take 02 for an A=0 point?
    In the oracle, yes. MH200N (010108), F454 (020051), F459 (020105) and F453AV (030014) all ACK *1*1*02## and *1*1*02#4#01##, and put a telegram on the bus that differs from the one for *1*1*2##, so it is a point-to-point address and not area 2. The four-digit *1*1*0002## is NACKed or dropped by every emulated gateway (the MH202 ACKs it but turns it into *1*1000#1*02##), so the 4-digit form is not the one to use for A=0.
    Caveat: your MH200 2.1.2 NACKs 02, and the emulated MH200N ACKs it. They are different models and the oracle runs emulated firmware, so I can't promise a replacement gateway behaves the same. If you can borrow an MH200N or F454 to try *1*1*02##, that is the test that decides it.

    2. F460 NACKing WHO 1/2.
    The oracle reproduces it: the F460 (020012) and F461 (020011) NACK every *1*1*… variant I tried, so it looks like it simply does not take OWN lighting commands. Your live F460 also NACKs status requests; the emulation ACKs *#1*2##, so the emulation differs from your unit there.

    3. Why does a press trigger an area-2 burst?
    Your capture shows it clearly. The press emits *1*1*2## / *1*0*2##, and 0.1-1.1 s later the gateway sends *1*0*21## .. *1*0*29##, about 40-50 ms apart. That is what a refresh of area 2 looks like, so your hypothesis (the MH200 reads WHERE 2 as area 2) fits. Your two planned tests, a normal point and the F460 disconnected, will tell the MH200 and the F460 apart; the capture alone can't.

    What this means for MyHOME

    • A=0 PL=2 and area 2 are the same frame on the wire (*1*1*2##), so MyHOME cannot tell them apart from the frame alone. The guard against single-digit WHEREs stays.
    • For commands, the two-digit 02 is the form to aim for. I'm looking at an opt-in for a YAML light declared as 02, but I can only test it on the emulated firmware, so I will need your hardware to confirm it.
    • I added your press capture as a test fixture, credited to you, in test(fixtures): A=0 PL=2 physical press trace from an MH200 (#684) #700 (fixture and tests only, no behaviour change).

    WHAT 19. I can't say yet whether it is strictly a fault. Your six extra actuators carry a *#1001 DIM 11 mask like the one I saw on another MH200, and the bit meanings are not documented. Your masks differ per device (…01100111 vs …11100111), so treat them as evidence only. In the current beta, WHAT 19 sets the light to unknown (not off) instead of failing.

    Session limit. Thanks for the reset/refuse pattern (back after about 7 minutes). I'll check how MyHOME backs off when it sees that.

  5. GreenGrassBlueOcean commented on Oct 13, 2026

    @GreenGrassBlueOcean
    ContributorAuthor

    @peterbeepping one more request: do you still have the original MH200 firmware, for example the MH200_2_1_2.fwz service pack you mentioned or the installation CD-ROM that came with the gateway (and, if it's a different file, the 2.1.0 one)?

    The firmware oracle (OpenWebNet-HA/own-firmware-oracle) so far only emulates the MH200N, which accepts *1*1*02## where your physical MH200 2.1.2 NACKs it. With the real MH200 firmware we could replay these frames and see why, instead of guessing from the model difference. Only the firmware file is needed, no capture or access to your gateway.

  6. added 3 commits that reference this issue on Oct 13, 2026
  7. gdluck commented on Oct 15, 2026

    @gdluck

    Another data point, F461 firmware 2.0.11 on a Home + Project plant with an F411/4 (channels at A=0 PL=6 and PL=7, earlier today PL=1 and PL=4): *#1*06## answers *1*0*06## and *1*1*06## switches the light; *#1*0006## is NACKed in 14 ms; *#1*6## is ACKed after 1.0 s with no reply and *1*1*6## is echoed as an area-6 command with no light reacting. On this gateway the 2-digit 0P form is the only working one (the F461 itself emits *1*1*06##), the 4-digit form is refused and single digits are areas, the opposite of the MH200 2.1.0 behaviour in the report.

  8. peterbeepping commented on Oct 15, 2026

    @peterbeepping

    I solved the problem in my home by using an old touchscreen (my home touchscreen 3,5" axolute h4890) as the openweb gateway. This old touchscreen handles the zero adresses correctly.
    I asked and got the old firmware of the mh200 from Legrand support. I'm going to try to update the mh200 with it. Maybe then it will work again. But you were also interested in it, so I included the file in this post. I don't have the original cd rom.

    MH200_020102.zip

  9. GreenGrassBlueOcean commented on Oct 21, 2026

    @GreenGrassBlueOcean
    ContributorAuthor

    Resolved in PR #700 (2c3531c7) and PR #713 (3d033ebc), with additional live F461 Area-0 (WHERE 06, 07) hardware verification in PR #752 (1b3486cf) and PR #753 (0f7ae38d). Thank you @peterbeepping and @gdluck for the traces and firmware data!

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Metadata

Metadata

Assignees

No one assigned

    Labels

    bugSomething isn't workingenhancementNew feature or request

    Type

    No type

    Projects

    No projects

      Milestone

      No milestone

      Relationships

      None yet

      Development

      No branches or pull requests

      Issue actions