Skip to content

Request humidity on startup. #710

Closed
Closed

Description

@lyubomirtraykov

The integration must send *#4*0*60## on startup so all the climate zones could report the current humidity. Now the integration reports the humidity only when there is change and a frame is monitored on the BUS. The more elegant solution would be if the climate zone remembers that it supports humidity and only query the climate zones that supports it on startup

Activity

  1. GreenGrassBlueOcean commented on Oct 14, 2026

    @GreenGrassBlueOcean
    Contributor

    Thanks for reporting this @lyubomirtraykov!

    We have opened #712 implementing your second (more elegant) suggestion:

    • When a climate zone reports humidity (*#4*<zone>*60*<humidity>##), or when Home Assistant restarts and restores a climate entity that previously had current_humidity in its state attributes (or has humidity: true configured), the zone remembers that it supports humidity (_humidity = True) and restores the last known current_humidity.
    • On startup (once the initial discovery sweep finishes), only climate zones with _humidity = True send a targeted *#4*<zone>*60## status request — even on physical gateways like the F461 where dimensionless *#4*<zone>## polling is skipped.

    Request for Bus Traces (for #710 / #712 and other open Climate PRs)

    Since you have an F461 gateway with standalone humidity/fancoil climate zones, could you share a few bus captures (via the MyHOME Bus Monitor card export or integration Diagnostics download) if you have a moment? We currently have several open climate PRs/issues waiting for real-hardware traces:

    1. Humidity queries (Request humidity on startup. #710 / feat(climate): remember zone humidity support and query dimension 60 on startup (#710) #712):
    2. Standalone vs #-prefixed setpoint writes (Setting a zone's target temperature fails on a 99-zone central plant: zone is addressed as *#4*3*#14*... instead of `*#4*#3*#14* #697):
    3. Open climate mode / season / programme PRs ([BLOCKED: PENDING TRACES] test: accept the OWNd#88 holiday readings for 13xxx/23xxx #650, Climate: show antifreeze (102) and thermal protection (202) of the central unit instead of both as off #699, OpenWebNet-HA/OWNd#97):
      • If you switch a thermostat on the wall (or via its native app) between Heating / Cooling / Off / Auto (Programme) / Manual (or holiday/vacation mode if supported), a bus trace of the emitted *4*...## and *#4*...## frames would be hugely helpful to validate our open climate PRs.

    Thanks again for your help!

  2. added a commit that references this issue on Oct 14, 2026
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment