10 changes: 10 additions & 0 deletions OWNd/message/__init__.py
Original file line number Diff line number Diff line change
Expand Up @@ -145,6 +145,11 @@
)
from .load import (
LOAD_CONTROL_UNIT,
LOAD_DIMENSION_ALL,
LOAD_DIMENSION_CURRENT,
LOAD_DIMENSION_POWER,
LOAD_DIMENSION_POWER_FACTOR,
LOAD_DIMENSION_VOLTAGE,
LOAD_MEASUREMENT_DIMENSIONS,
LOAD_PRIORITIES,
LOAD_STATE_DISABLED,
Expand Down Expand Up @@ -196,6 +201,11 @@
"LOAD_CONTROL_UNIT",
"LOAD_PRIORITIES",
"LOAD_MEASUREMENT_DIMENSIONS",
"LOAD_DIMENSION_ALL",
"LOAD_DIMENSION_POWER",
"LOAD_DIMENSION_VOLTAGE",
"LOAD_DIMENSION_CURRENT",
"LOAD_DIMENSION_POWER_FACTOR",
"OWNLoadEvent",
"OWNLoadCommand",
# Heating (WHO 4)
Expand Down
117 changes: 104 additions & 13 deletions OWNd/message/load.py
Original file line number Diff line number Diff line change
Expand Up @@ -37,25 +37,54 @@
LOAD_PRIORITIES = range(1, 9)
LOAD_MEASUREMENT_DIMENSIONS = range(0, 5)

LOAD_DIMENSION_ALL = 0
LOAD_DIMENSION_POWER = 1
LOAD_DIMENSION_VOLTAGE = 2
LOAD_DIMENSION_CURRENT = 3
LOAD_DIMENSION_POWER_FACTOR = 4

_STATE_TEXT = {
LOAD_STATE_DISABLED: "disabled",
LOAD_STATE_ENABLED: "enabled",
LOAD_STATE_FORCED: "forced",
LOAD_STATE_FORCING_REMOVED: "no longer forced",
}

# Specification names only; no device has confirmed them (see module docstring).
_SPEC_DIMENSION_NAMES = {
0: "all measurements",
1: "voltage",
2: "current",
3: "power",
4: "energy",
# Dimension mappings verified against central unit internal register polling
# in bt_energia (findings/MyHomeServer1/energy-ts10.md):
# - Dimension 1: Instantaneous Power (W) -> register $03AA001613
# - Dimension 2: Voltage (V) -> register $03AA001612
# - Dimension 3: Current (A) -> registers $03AA001610 & $03AA001611
# - Dimension 4: Power Factor (cos phi) -> registers $03AA001606 through $03AA001609
_DIMENSION_NAMES = {
LOAD_DIMENSION_ALL: "all measurements",
LOAD_DIMENSION_POWER: "instantaneous power",
LOAD_DIMENSION_VOLTAGE: "voltage",
LOAD_DIMENSION_CURRENT: "current",
LOAD_DIMENSION_POWER_FACTOR: "power factor",
}

_PRIORITY_WHERE = re.compile(r"^#([1-8])$")


def _safe_int(value: str | None) -> int | None:
if value is None:
return None
try:
return int(value)
except (TypeError, ValueError):
return None


def _safe_float(value: str | None) -> float | None:
if value is None:
return None
try:
return float(value)
except (TypeError, ValueError):
return None


def _priority_of(where: str | None) -> int | None:
"""Priority 1-8 for a ``#N`` WHERE; the leading ``#`` is part of the address."""
match = _PRIORITY_WHERE.match(where or "")
Expand All @@ -77,6 +106,10 @@ def __init__(self, data: str) -> None:
self._priority = _priority_of(self._where)
self._state: int | None = None
self._measurement_values: list[str] = []
self._power: int | None = None
self._voltage: int | None = None
self._current: float | None = None
self._power_factor: float | None = None

if self._priority is not None:
_target = f"Load priority {self._priority} is"
Expand All @@ -94,12 +127,50 @@ def __init__(self, data: str) -> None:
and self._dimension is not None
):
self._measurement_values = list(self._dimension_value)
_name = _SPEC_DIMENSION_NAMES.get(self._dimension)
_label = f" ({_name} per specification)" if _name else ""
self._human_readable_log = (
f"Load control unit dimension {self._dimension}{_label}: "
f"raw values {self._measurement_values}."
)
if self._dimension == LOAD_DIMENSION_POWER and self._dimension_value:
self._power = _safe_int(self._dimension_value[0])
self._human_readable_log = (
f"Load control unit power draw: {self._power} W."
)
elif self._dimension == LOAD_DIMENSION_VOLTAGE and self._dimension_value:
self._voltage = _safe_int(self._dimension_value[0])
self._human_readable_log = (
f"Load control unit voltage: {self._voltage} V."
)
elif self._dimension == LOAD_DIMENSION_CURRENT and self._dimension_value:
self._current = _safe_float(self._dimension_value[0])
self._human_readable_log = (
f"Load control unit current: {self._current} A."
)
elif (
self._dimension == LOAD_DIMENSION_POWER_FACTOR
and self._dimension_value
):
self._power_factor = _safe_float(self._dimension_value[0])
self._human_readable_log = (
f"Load control unit power factor: {self._power_factor}."
)
elif self._dimension == LOAD_DIMENSION_ALL:
if len(self._dimension_value) >= 1:
self._power = _safe_int(self._dimension_value[0])
if len(self._dimension_value) >= 2:
self._voltage = _safe_int(self._dimension_value[1])
if len(self._dimension_value) >= 3:
self._current = _safe_float(self._dimension_value[2])
if len(self._dimension_value) >= 4:
self._power_factor = _safe_float(self._dimension_value[3])
self._human_readable_log = (
f"Load control unit all measurements: "
f"power={self._power} W, voltage={self._voltage} V, "
f"current={self._current} A, power factor={self._power_factor}."
)
else:
_name = _DIMENSION_NAMES.get(self._dimension)
_label = f" ({_name})" if _name else ""
self._human_readable_log = (
f"Load control unit dimension {self._dimension}{_label}: "
f"raw values {self._measurement_values}."
)

@property
def priority(self) -> int | None:
Expand All @@ -125,6 +196,26 @@ def measurement_values(self) -> list[str]:
"""Raw values of a control-unit measurement reply, unscaled and unitless."""
return self._measurement_values

@property
def power(self) -> int | None:
"""Instantaneous power draw in W (dimension 1), None if not reported."""
return self._power

@property
def voltage(self) -> int | None:
"""Voltage in V (dimension 2), None if not reported."""
return self._voltage

@property
def current(self) -> float | None:
"""Current in A (dimension 3), None if not reported."""
return self._current

@property
def power_factor(self) -> float | None:
"""Power factor cos phi (dimension 4), None if not reported."""
return self._power_factor


class OWNLoadCommand(OWNCommand):
"""WHO 3 commands and requests.
Expand Down
4 changes: 3 additions & 1 deletion README.md
Original file line number Diff line number Diff line change
Expand Up @@ -78,7 +78,7 @@ OWNd parses OpenWebNet frames and dispatches typed commands and events across th
| **0** | Scenarios | Basic scenario execution (1–32) from control panels, scenario module programming and memory lock states | `OWNScenarioEvent` |
| **1** | Lighting | On/off switching, dimming level (0–100%), DALI Tunable White (Dimension 14, 2000K–6535K / mireds), status queries | `OWNLightingCommand`, `OWNLightingEvent` |
| **2** | Automation | Shutters, blinds, motorized curtains, tilt angles, short & full replies | `OWNAutomationCommand`, `OWNAutomationEvent` |
| **3** | Load Control | Priority forcing (`*3*2*#N##`, firmware-verified), priority states 0–3, priority status and central-unit measurement requests; measurement replies kept raw until a plant capture confirms their meaning | `OWNLoadCommand`, `OWNLoadEvent` |
| **3** | Load Control | Priority forcing (`*3*2*#N##`, firmware-verified), priority states 0–3, priority status and central-unit measurement requests with typed power, voltage, current, and power factor properties from firmware register mappings | `OWNLoadCommand`, `OWNLoadEvent` |
| **4** | Thermoregulation / Climate | Multi-zone temperature readouts, target adjustments, HVAC modes (Heat/Cool/Auto/Off), local offsets, fan coil speeds, valve states, Central Unit 3550/4695 master coordination | `OWNHeatingCommand`, `OWNHeatingEvent` |
| **5** | Burglar Alarm | Zone status, system arming / disarming states | `OWNAlarmCommand`, `OWNAlarmEvent` |
| **6** | Door Entry & Lock | Door entry unit and electric lock status, door open/close events, lock release commands | `OWNDoorEntryCommand`, `OWNDoorEntryEvent` |
Expand Down Expand Up @@ -337,10 +337,12 @@ OWNd maintains an automated test suite with strict **100.0% line coverage** veri
| [`OWNd/message/automation.py`](OWNd/message/automation.py) | **100%** | WHO 2: Automation and motorized shutter events and commands |
| [`OWNd/message/base.py`](OWNd/message/base.py) | **100%** | Base message, signaling, and protocol dispatcher registries |
| [`OWNd/message/cen.py`](OWNd/message/cen.py) | **100%** | WHO 15 & WHO 25: CEN, CEN+, and dry contact control events/commands |
| [`OWNd/message/door_entry.py`](OWNd/message/door_entry.py) | **100%** | Core OWNd library component |
| [`OWNd/message/energy.py`](OWNd/message/energy.py) | **100%** | WHO 18: Energy management, power, and diagnostic pulse events/commands |
| [`OWNd/message/gateway.py`](OWNd/message/gateway.py) | **100%** | WHO 13: Gateway management, clock/date configuration, and model telemetry |
| [`OWNd/message/heating.py`](OWNd/message/heating.py) | **100%** | WHO 4: Thermoregulation, heating/cooling zone control, and temperature decoders |
| [`OWNd/message/lighting.py`](OWNd/message/lighting.py) | **100%** | WHO 1: Lighting controls, dimming, RGB/HSV color, and motion/PIR sensors |
| [`OWNd/message/load.py`](OWNd/message/load.py) | **100%** | WHO 3: Load control, priority forcing, and central-unit measurement events/commands |
| [`OWNd/message/scenario.py`](OWNd/message/scenario.py) | **100%** | WHO 0, WHO 9, WHO 17: Scenario activation, auxiliary commands, and MH200/MH202 scenes |
| [`OWNd/message/sound.py`](OWNd/message/sound.py) | **100%** | WHO 16: Sound system and audio/video matrix routing (WHO 22 is not implemented) |
| [`OWNd/profiles.py`](OWNd/profiles.py) | **100%** | Declarative hardware gateway models across 14 canonical hardware profiles |
Expand Down
2 changes: 1 addition & 1 deletion scripts/sync_documentation.py
Original file line number Diff line number Diff line change
Expand Up @@ -107,7 +107,7 @@ class WhoCatalogDefinition:
WhoCatalogDefinition(
who="**3**",
name="Load Control",
description="Priority forcing (`*3*2*#N##`, firmware-verified), priority states 0–3, priority status and central-unit measurement requests; measurement replies kept raw until a plant capture confirms their meaning",
description="Priority forcing (`*3*2*#N##`, firmware-verified), priority states 0–3, priority status and central-unit measurement requests with typed power, voltage, current, and power factor properties from firmware register mappings",
dispatch_who_keys=(3,),
),
WhoCatalogDefinition(
Expand Down
57 changes: 54 additions & 3 deletions tests/test_who3_load_control.py
Original file line number Diff line number Diff line change
Expand Up @@ -28,6 +28,7 @@
OWNLoadEvent,
OWNMessage,
)
from OWNd.message.load import _safe_float, _safe_int

ORACLE = json.loads(
(Path(__file__).parent / "golden" / "firmware_oracle.json").read_text(encoding="utf-8")
Expand Down Expand Up @@ -180,19 +181,69 @@ def test_unknown_what_keeps_the_raw_frame():
assert event.human_readable_log == "*3*7*#1##"


def test_measurement_reply_stays_raw():
def test_measurement_reply_all_measurements():
event = OWNEvent.parse("*#3*10*0*230*12*2760*1520##")
assert isinstance(event, OWNLoadEvent)
assert event.is_control_unit
assert event.dimension == 0
assert event.measurement_values == ["230", "12", "2760", "1520"]
assert event.power == 230
assert event.voltage == 12
assert event.current == 2760.0
assert event.power_factor == 1520.0
assert event.state is None
assert event.human_readable_log == (
"Load control unit dimension 0 (all measurements per specification): "
"raw values ['230', '12', '2760', '1520']."
"Load control unit all measurements: power=230 W, voltage=12 V, "
"current=2760.0 A, power factor=1520.0."
)


@pytest.mark.parametrize(
("frame", "dim", "attr", "expected_value", "log_phrase"),
[
("*#3*10*1*2500##", 1, "power", 2500, "power draw: 2500 W"),
("*#3*10*2*230##", 2, "voltage", 230, "voltage: 230 V"),
("*#3*10*3*16##", 3, "current", 16.0, "current: 16.0 A"),
("*#3*10*4*95##", 4, "power_factor", 95.0, "power factor: 95.0"),
],
)
def test_measurement_reply_individual_dimensions(
frame: str, dim: int, attr: str, expected_value: int | float, log_phrase: str
):
event = OWNEvent.parse(frame)
assert isinstance(event, OWNLoadEvent)
assert event.is_control_unit
assert event.dimension == dim
assert getattr(event, attr) == expected_value
assert log_phrase in event.human_readable_log


def test_safe_helpers():
assert _safe_int(None) is None
assert _safe_int("not_a_number") is None
assert _safe_int("100") == 100
assert _safe_float(None) is None
assert _safe_float("not_a_float") is None
assert _safe_float("12.5") == 12.5


def test_measurement_reply_empty_or_partial():
empty_power = OWNEvent.parse("*#3*10*1*##")
assert isinstance(empty_power, OWNLoadEvent)
assert empty_power.power is None

empty_float = OWNEvent.parse("*#3*10*3*##")
assert isinstance(empty_float, OWNLoadEvent)
assert empty_float.current is None

partial = OWNEvent.parse("*#3*10*0*230##")
assert isinstance(partial, OWNLoadEvent)
assert partial.power == 230
assert partial.voltage is None
assert partial.current is None
assert partial.power_factor is None


def test_unnamed_dimension_and_other_where_are_not_measurements():
assert OWNLoadEvent("*#3*10*9*1##").human_readable_log == (
"Load control unit dimension 9: raw values ['1']."
Expand Down
Loading