13 changes: 9 additions & 4 deletions OWNd/message/gateway.py
Original file line number Diff line number Diff line change
Expand Up @@ -123,10 +123,15 @@ def __init__(self, data: str) -> None:
elif self._dimension_value[0] == "13":
self._device_type = "H4684"
elif self._dimension_value[0] == "200":
# Code 200 is shared by every Linux-based gateway generation seen so
# far (F454, MyHomeServer1, MH202, F461, H4890; MyHOME #370, #466 and
# the F461 plant capture). WHO 1013 dimension 1 tells them apart.
self._device_type = "F454 / MyHomeServer1 / MH202 / F461 / H4890"
# Code 200 is shared across modern gateways (F454, MyHomeServer1,
# MH202, F461, H4890; plus emulated F450/F459/F460 in trace-corpus.tsv)
# and MH201 (fw 3.3.6, 3.6.27; MyHOME #370, #466 and plant fixtures;
# catalogued on 030644 outside the Linux QEMU fleet). WHO 1013
# dimension 1 tells them apart (the MH201 on 3.6.27 answers only
# *#1013**1##, model 10, and NACKs *#1013*0*1##).
self._device_type = (
"F454 / MyHomeServer1 / MH202 / F461 / H4890 / MH201"
)
else:
self._device_type = f"Unknown ({self._dimension_value[0]})"
self._human_readable_log = f"Gateway device type is: {self._device_type}."
Expand Down
18 changes: 9 additions & 9 deletions OWNd/message/heating.py
Original file line number Diff line number Diff line change
Expand Up @@ -505,7 +505,6 @@ def __init__(self, data: str) -> None:
self._type = MESSAGE_TYPE_ACTION
self._is_cooling = self._dimension_value[0] in _valve_active_states
self._is_heating = self._dimension_value[1] in _valve_active_states
self._is_active = self._is_cooling | self._is_heating
# Handle cooling valve status relative to fan speed/status
_cooling_value = int(self._dimension_value[0])
if _cooling_value == 0:
Expand All @@ -528,7 +527,6 @@ def __init__(self, data: str) -> None:
_fan_mode = _cooling_value - 5
if _fan_mode > 0:
self._cooling_fan_on = True
self._is_active = True
self._cooling_fan_speed = _fan_mode
self._human_readable_log = f"Zone {self._zone}'s cooling fan is on at speed {self._cooling_fan_speed}" # pylint: disable=line-too-long
else:
Expand All @@ -550,7 +548,6 @@ def __init__(self, data: str) -> None:
_fan_mode = _heating_value - 5
if _fan_mode > 0:
self._fan_on = True
self._is_active = True
self._fan_speed = _fan_mode
self._human_readable_log += (
f"; heating fan is on at speed {self._fan_speed}."
Expand All @@ -560,7 +557,7 @@ def __init__(self, data: str) -> None:
self._human_readable_log += "; heating fan is off."
# A fan-coil value on one side must not hide an open valve or a running fan
# on the other side: *#4*2*19*5*1## (cooling fan off, heating valve on) is an
# active zone (F461 plant capture, tests/fixtures/f461_live_2026-10-15/).
# active zone (F461 plant capture, tests/test_f461_live_plant.py).
self._is_active = bool(
self._is_cooling
or self._is_heating
Expand Down Expand Up @@ -923,13 +920,16 @@ def set_mode(
mode_name = mode
if mode == CLIMATE_MODE_AUTO:
# Automatic is the central unit's program: the firmware refuses *4*311*Z##
# (NACK, no bus frame; OWNd#77 A3, oracle3/out/termo_f461.tsv) and only
# forwards *4*311*#Z##, a frame addressed to the central unit, so
# (NACK, no bus frame across all 11 emulated gateways in thermo-zone-mode.tsv
# and ownd-pr82-heating.tsv; OWNd#77 A3) and only forwards *4*311*#Z##, a
# frame addressed to the central unit (bus D1 00 03 02 C2 ZZ 00 00), so
# standalone does not apply. Protection (302 / 102 / 202) is different:
# the plain zone form is forwarded as a direct zone command (bus
# 93 ZZ 30 04) and is the only form a standalone thermostat acts on;
# the #Z form goes to a central unit and is ignored when there is none
# (F461 plant capture, tests/fixtures/f461_live_2026-10-15/).
# 93 ZZ 30 04, like *4*303*Z## -> 93 ZZ 30 0F in thermo-zone-mode.tsv)
# and is the only form a standalone thermostat acts on; the #Z form goes
# to a central unit (bus D1 00 03 02 C2 ZZ 07 00 in thermo-ts10.tsv) and
# is ignored when there is none (F461 plant capture,
# tests/test_f461_live_plant.py).
if not zone.startswith("#"):
zone = f"#{zone}"

Expand Down
2 changes: 1 addition & 1 deletion README.md
Original file line number Diff line number Diff line change
Expand Up @@ -337,7 +337,7 @@ OWNd maintains an automated test suite with strict **100.0% line coverage** veri
| [`OWNd/message/automation.py`](OWNd/message/automation.py) | **100%** | WHO 2: Automation and motorized shutter events and commands |
| [`OWNd/message/base.py`](OWNd/message/base.py) | **100%** | Base message, signaling, and protocol dispatcher registries |
| [`OWNd/message/cen.py`](OWNd/message/cen.py) | **100%** | WHO 15 & WHO 25: CEN, CEN+, and dry contact control events/commands |
| [`OWNd/message/door_entry.py`](OWNd/message/door_entry.py) | **100%** | WHO 6 & WHO 8: Door entry, lock, and video intercom events and commands |
| [`OWNd/message/door_entry.py`](OWNd/message/door_entry.py) | **100%** | WHO 6 & WHO 8: Door entry, electric lock, and video intercom events/commands |
| [`OWNd/message/energy.py`](OWNd/message/energy.py) | **100%** | WHO 18: Energy management, power, and diagnostic pulse events/commands |
| [`OWNd/message/gateway.py`](OWNd/message/gateway.py) | **100%** | WHO 13: Gateway management, clock/date configuration, and model telemetry |
| [`OWNd/message/heating.py`](OWNd/message/heating.py) | **100%** | WHO 4: Thermoregulation, heating/cooling zone control, and temperature decoders |
Expand Down
2 changes: 1 addition & 1 deletion scripts/sync_documentation.py
Original file line number Diff line number Diff line change
Expand Up @@ -60,7 +60,7 @@
"OWNd/message/automation.py": "WHO 2: Automation and motorized shutter events and commands",
"OWNd/message/base.py": "Base message, signaling, and protocol dispatcher registries",
"OWNd/message/cen.py": "WHO 15 & WHO 25: CEN, CEN+, and dry contact control events/commands",
"OWNd/message/door_entry.py": "WHO 6 & WHO 8: Door entry, lock, and video intercom events and commands",
"OWNd/message/door_entry.py": "WHO 6 & WHO 8: Door entry, electric lock, and video intercom events/commands",
"OWNd/message/energy.py": "WHO 18: Energy management, power, and diagnostic pulse events/commands",
"OWNd/message/gateway.py": "WHO 13: Gateway management, clock/date configuration, and model telemetry",
"OWNd/message/heating.py": "WHO 4: Thermoregulation, heating/cooling zone control, and temperature decoders",
Expand Down
12 changes: 7 additions & 5 deletions tests/test_f461_live_plant.py
Original file line number Diff line number Diff line change
Expand Up @@ -14,11 +14,13 @@
valve states had set it. The plant reports this frame on every heating-season read.
2. ``set_mode(zone, "protection" | "antifreeze" | "thermal_protection", standalone=True)``
produced the ``#Z`` form, which the gateway forwards to a central unit (emulated
``bt_termo``: ``*4*302*#23##`` -> ``D1 00 03 02 C2 17 07 00``) and which a standalone
thermostat ignores; the plain form (``93 17 30 04``) is the one that works. Only
``311`` (automatic) is a central-unit-only command (``*4*311*Z##`` is NACKed).
``bt_termo``: ``*4*302*#23##`` -> ``D1 00 03 02 C2 17 07 00`` in ``thermo-ts10.tsv``)
and which a standalone thermostat ignores; the plain form (``93 17 30 04``) is the one
that works. Only ``311`` (automatic) is a central-unit-only command (``*4*311*Z##`` is
NACKed across all 11 emulated gateways in ``thermo-zone-mode.tsv``).
3. WHO 13 device type ``200`` was labelled ``F454`` although F454, MyHomeServer1, MH202,
F461 and H4890 all answer it.
F461, H4890 and MH201 (fw 3.3.6, 3.6.27; plus emulated F450/F459/F460 in
``trace-corpus.tsv``) all answer it.
"""
from __future__ import annotations

Expand Down Expand Up @@ -178,7 +180,7 @@ def test_capture_shows_only_the_plain_protection_form_acts() -> None:
def test_device_type_200_is_not_a_single_model() -> None:
msg = OWNEvent.parse("*#13**15*200##")
assert msg.device_type_code == "200"
assert "F454" in msg.device_type and "F461" in msg.device_type
assert "F454" in msg.device_type and "F461" in msg.device_type and "MH201" in msg.device_type
assert msg.human_readable_log == f"Gateway device type is: {msg.device_type}."
assert OWNEvent.parse("*#13**15*2##").device_type == "MHServer"
assert OWNEvent.parse("*#13**16*2*0*11##").device_type_code is None
Expand Down
2 changes: 1 addition & 1 deletion tests/test_profiles.py
Original file line number Diff line number Diff line change
Expand Up @@ -550,7 +550,7 @@ def test_owngateway_event_properties() -> None:
assert evt_fw.device_type is None

evt_dev = OWNGatewayEvent("*#13**15*200##")
assert evt_dev.device_type == "F454 / MyHomeServer1 / MH202 / F461 / H4890"
assert evt_dev.device_type == "F454 / MyHomeServer1 / MH202 / F461 / H4890 / MH201"
assert evt_dev.device_type_code == "200"
assert evt_dev.firmware_version is None

Expand Down