1 change: 1 addition & 0 deletions CHANGELOG.md
Original file line number Diff line number Diff line change
Expand Up @@ -16,6 +16,7 @@ All notable changes to `OWNd` are documented in this file.
### Fixed
- **WHO 4 Dimension 22 is never sent**: Dimension 22 is the published split-unit IR control (`*#4*3#Z#N*22##` / `*#4*3#Z#N*#22*MOD*SP*VEL*SWING##`, WHO 4 specification pp. 66-68); in any spelling (`*#4*ZONE*22##`, `*#4*#0*22##`, leading zeros, whitespace or `+` tokens) it crashes the thermoregulation daemon (`bt_termo`) on Linux IP gateways and reboots an F461 2.0.11 about three minutes later (own-firmware-oracle `tools/expected_divergences.yaml` crash frames, live F461 2.0.11). `OWNCommandSession.send` (and so `AsyncTcpTransport.send` and `keepalive`), `OWNCommandSession.send_to_gateway` (before `connect()`: no socket, no handshake) and `AsyncSerialTransport.send` refuse it before anything is written, with the contract above and `reason="destructive_frame"`. The detector `is_who4_dimension_22()` is public, accepts `bytes`, and is anchored to the first `*` of each frame, so a mid-frame WHERE `#4` / DIMENSION `#4` such as `*#2*#4*#11#001*22##` or `*#1*14*#4*1*22##` stays sendable. Parsing is unchanged: the frame can still be read from the bus.
- **`AsyncSerialTransport.send` validates outbound frames** like `OWNCommandSession.send`: an invalid or signaling frame (for example the single-`#` concatenation `*1*1*11#*#4*2*22##`) is refused with `reason="invalid_frame"` instead of being written to the port. The frame is serialised once, terminator included: the string checked is the string written.
- **WHO 4 (`OWNHeatingCommand.central_status`)**: the deprecation text said gateways refuse `*#4*WHERE*14##`; six of the twelve emulated gateways forward it to the bus (own-firmware-oracle `trace-corpus`) and it is simply unanswered without a central unit. The warning now points to `status('#0')`. The frame is unchanged.

## [2.0.0b11] - 2026-10-20

Expand Down
29 changes: 20 additions & 9 deletions OWNd/message/heating.py
Original file line number Diff line number Diff line change
Expand Up @@ -1328,17 +1328,28 @@ def set_timed_manual_end_time(

@classmethod
def central_status(cls, where: str = "#0") -> OWNHeatingCommand:
"""Deprecated: builds ``*#4*WHERE*14##``, which gateways refuse.

A real MyHomeServer1 3.1.8 (OWNd#77 gateway probe) answers ``*#*0##``
(NACK); on an F454 (MyHOME#629) dimension 14 silently timed out while
``status("#0")`` (``*#4*#0##``) answered within 0.13 s. Use
``status(where)`` to poll a central unit. The frame is kept unchanged
for existing callers.
"""Deprecated: builds ``*#4*WHERE*14##``, unanswered without a central unit.

In the firmware oracle (``trace-corpus``) F453, F453AV, F460, F461,
MH200N and MyHomeServer1 forward ``*#4*#0*14##`` to the bus
(``nack``/``out``), while F450, F454, F459, H4684, MH200 and MH202
refuse it (``nack``/``silent``). Forwarded or not, only a central unit
answers it: a live F461 2.0.11 without one NACKs it after the bus
timeout, a live MyHomeServer1 3.87.13 without one NACKs it after
~4.2 s, a real MyHomeServer1 3.1.8 (OWNd#77 gateway probe) NACKs it,
and on an F454 (MyHOME#629) it timed out while ``status("#0")``
(``*#4*#0##``) answered within 0.13 s. The Legrand WHO 4 document
defines the dimension 14 read on zones 1..99 only (p. 18) and, on
``#0``, reads of dimensions 30 and 31 (pp. 57-58): ``*#4*#0*14##`` is
undefined there, and the central unit's set point comes back inside
the ``*4*110#T*#0##`` reply to ``*#4*#0##`` (p. 56). Use
``status('#0')`` (or ``status(where)``) to poll a central unit. The
frame is kept unchanged for existing callers.
"""
warnings.warn(
"OWNHeatingCommand.central_status() builds *#4*WHERE*14##, which gateways "
"refuse; use OWNHeatingCommand.status(where) instead",
"OWNHeatingCommand.central_status() builds *#4*WHERE*14##, which goes "
"unanswered without a central unit; use OWNHeatingCommand.status('#0') "
"(OWNHeatingCommand.status(where)) instead",
DeprecationWarning,
stacklevel=2,
)
Expand Down
39 changes: 39 additions & 0 deletions tests/test_who4_central_status_text.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,39 @@
"""``central_status`` deprecation text names the real reason.

``*#4*#0*14##`` is forwarded to the bus by F453, F453AV, F460, F461, MH200N
and MyHomeServer1 in the firmware oracle (``trace-corpus``, ``nack``/``out``)
and refused by the other six; either way it goes unanswered without a
central unit. The frame is unchanged.
"""

from __future__ import annotations

import warnings

from OWNd.message import OWNHeatingCommand


def test_central_status_deprecation_names_the_real_reason() -> None:
doc = OWNHeatingCommand.central_status.__doc__ or ""
assert "which gateways refuse" not in doc
assert "unanswered without a central unit" in doc
assert "trace-corpus" in doc
assert "F461" in doc

with warnings.catch_warnings(record=True) as caught:
warnings.simplefilter("always")
command = OWNHeatingCommand.central_status("#0")
assert str(command) == "*#4*#0*14##"
(warning,) = caught
assert issubclass(warning.category, DeprecationWarning)
text = str(warning.message)
assert "refuse" not in text
assert "unanswered without a central unit" in text
assert "status('#0')" in text


def test_central_status_frame_and_default_are_unchanged() -> None:
with warnings.catch_warnings():
warnings.simplefilter("ignore", DeprecationWarning)
assert str(OWNHeatingCommand.central_status()) == "*#4*#0*14##"
assert str(OWNHeatingCommand.central_status("#0#1")) == "*#4*#0#1*14##"