2 changes: 2 additions & 0 deletions OWNd/message/__init__.py
Original file line number Diff line number Diff line change
Expand Up @@ -40,6 +40,7 @@
MESSAGE_TYPE_ACTIVE_POWER,
MESSAGE_TYPE_CURRENT_DAY_CONSUMPTION,
MESSAGE_TYPE_CURRENT_MONTH_CONSUMPTION,
MESSAGE_TYPE_AUTO_UPDATE_INTERVAL,
MESSAGE_TYPE_DAILY_CONSUMPTION,
MESSAGE_TYPE_ENERGY_TOTALIZER,
MESSAGE_TYPE_HOURLY_CONSUMPTION,
Expand Down Expand Up @@ -201,6 +202,7 @@
"MESSAGE_TYPE_MONTHLY_CONSUMPTION",
"MESSAGE_TYPE_CURRENT_DAY_CONSUMPTION",
"MESSAGE_TYPE_CURRENT_MONTH_CONSUMPTION",
"MESSAGE_TYPE_AUTO_UPDATE_INTERVAL",
"_integer_value",
"OWNEnergyEvent",
"OWNEnergyCommand",
Expand Down
47 changes: 45 additions & 2 deletions OWNd/message/energy.py
Original file line number Diff line number Diff line change
Expand Up @@ -17,6 +17,7 @@
MESSAGE_TYPE_MONTHLY_CONSUMPTION = "monthly_consumption"
MESSAGE_TYPE_CURRENT_DAY_CONSUMPTION = "current_day_partial_consumption"
MESSAGE_TYPE_CURRENT_MONTH_CONSUMPTION = "current_month_partial_consumption"
MESSAGE_TYPE_AUTO_UPDATE_INTERVAL = "auto_update_interval"


def _integer_value(
Expand Down Expand Up @@ -45,6 +46,8 @@ def __init__(self, data: str) -> None:
self._current_day_partial_consumption = 0
self._monthly_consumption: dict[str, Any] = {}
self._current_month_partial_consumption = 0
self._update_interval: int | None = None
self._energy_type: int | None = None

if not where.startswith(("1", "5", "7")):
return
Expand Down Expand Up @@ -158,6 +161,16 @@ def __init__(self, data: str) -> None:
self._dimension_value, 0
)
self._human_readable_log = f"Sensor {self._sensor} is reporting a power consumption of {self._monthly_consumption['value']} Wh for {self._monthly_consumption['date'].strftime('%B %Y')}." # pylint: disable=line-too-long
elif self._dimension == 1200 and self._dimension_value:
# *#18*W*1200#type*time##: the meter confirms (time > 0) or
# ends (time = 0) the automatic power updates; libqtdevices
# re-arms the stream on time = 0 (energy_device.cpp:289-322,
# 719-726). type: 1 electricity, 2 gas, 3 heat, 4 water
# (energy_device.cpp:50-56).
self._type = MESSAGE_TYPE_AUTO_UPDATE_INTERVAL
self._update_interval = _integer_value(self._dimension_value, 0)
self._energy_type = _integer_value(self._dimension_param, 0, 0) if self._dimension_param else None
self._human_readable_log = f"Sensor {self._sensor} automatic updates every {self._update_interval} minutes (0 = stopped)." # pylint: disable=line-too-long
elif self._dimension == 53:
self._type = MESSAGE_TYPE_CURRENT_MONTH_CONSUMPTION
self._current_month_partial_consumption = _integer_value(
Expand All @@ -173,6 +186,16 @@ def message_type(self) -> str | None:
def sensor(self) -> str:
return self._sensor

@property
def update_interval(self) -> int | None:
"""Time field of a 1200 reply (minutes per Legrand WHO 18), 0 when stopped."""
return self._update_interval

@property
def energy_type(self) -> int | None:
"""Energy type of a 1200 reply (1 electricity, 2 gas, 3 heat, 4 water)."""
return self._energy_type

@property
def active_power(self) -> int:
return self._active_power
Expand Down Expand Up @@ -210,14 +233,34 @@ def human_readable_log(self) -> str:
class OWNEnergyCommand(OWNCommand):
@classmethod
def start_sending_instant_power(
cls, where: str | int, duration: int = 65
cls, where: str | int, duration: int = 65, energy_type: int = 1
) -> OWNEnergyCommand:
"""Start automatic updates: *#18*W*#1200#type*time##.

``duration`` is the Time field (1..255, minutes per Legrand WHO 18;
the meter answers *#18*W*1200#type*time##). ``energy_type`` 1 is
electricity, 2 gas, 3 heat, 4 water (libqtdevices energy_device.cpp:50-56).
"""
where = f"{where}#0" if str(where).startswith("7") else str(where)
duration = 255 if duration > 255 else duration
message = cls(f"*#18*{where}*#1200#1*{duration}##")
message = cls(f"*#18*{where}*#1200#{energy_type}*{duration}##")
message._human_readable_log = f"Requesting instant power draw update from sensor {where} for {duration} minutes." # pylint: disable=line-too-long
return message

@classmethod
def stop_sending_instant_power(
cls, where: str | int, energy_type: int = 1
) -> OWNEnergyCommand:
"""Stop automatic updates: *#18*W*#1200#type*0## (Time = 0).

Firmware replay on bt_supervisione: *#18*51*#1200#1*0## ACK, bus
D1 A1 02 32 00 02 1D 00; the meter then reports *#18*W*1200#type*0##.
"""
where = f"{where}#0" if str(where).startswith("7") else str(where)
message = cls(f"*#18*{where}*#1200#{energy_type}*0##")
message._human_readable_log = f"Stopping instant power draw updates from sensor {where}." # pylint: disable=line-too-long
return message

@classmethod
def get_hourly_consumption(
cls, where: str | int, date: datetime.date
Expand Down
56 changes: 56 additions & 0 deletions tests/test_who18_auto_update_reply.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,56 @@
"""WHO 18 dimension 1200 reply: *#18*W*1200#type*time## confirms (time > 0)
or ends (time = 0) the automatic power updates. libqtdevices TS10_1_0_23
energy_device.cpp:111 (_DIM_STATE_UPDATE_INTERVAL = 1200), :289-322
(handleAutomaticUpdate re-arms on time = 0), :719-726, :50-56 (energy types).
Firmware replay on bt_supervisione (MyHomeServer1, F454, F459, F461):
*#18*51*#1200#1*255## ACK bus D1 A1 02 32 00 02 1D FF, #1200#1*0 ... 1D 00,
#1200#2*255 ... 82 FF; the bare *#18*51*1200## is NACK with no bus frame."""

from OWNd.message import (
MESSAGE_TYPE_AUTO_UPDATE_INTERVAL,
OWNEnergyCommand,
OWNEnergyEvent,
OWNEvent,
)


def test_auto_update_confirmation_is_parsed():
msg = OWNEvent.parse("*#18*51*1200#1*255##")
assert isinstance(msg, OWNEnergyEvent)
assert msg.message_type == MESSAGE_TYPE_AUTO_UPDATE_INTERVAL
assert msg.update_interval == 255
assert msg.energy_type == 1
assert "255 minutes" in msg.human_readable_log


def test_auto_update_stop_is_parsed():
msg = OWNEvent.parse("*#18*51*1200#1*0##")
assert msg.message_type == MESSAGE_TYPE_AUTO_UPDATE_INTERVAL
assert msg.update_interval == 0


def test_other_dimensions_are_untouched():
msg = OWNEvent.parse("*#18*51*113*1234##")
assert msg.update_interval is None
assert msg.energy_type is None
assert msg.message_type != MESSAGE_TYPE_AUTO_UPDATE_INTERVAL


def test_message_type_is_exported():
import OWNd.message as message

assert "MESSAGE_TYPE_AUTO_UPDATE_INTERVAL" in message.__all__


def test_stop_builder_is_symmetrical_to_start():
start = OWNEnergyCommand.start_sending_instant_power(51, 255)
stop = OWNEnergyCommand.stop_sending_instant_power(51)
assert str(start) == "*#18*51*#1200#1*255##"
assert str(stop) == "*#18*51*#1200#1*0##"
assert "Stopping" in stop.human_readable_log


def test_builders_take_the_energy_type_and_the_7xx_address():
assert str(OWNEnergyCommand.start_sending_instant_power(51, 255, 2)) == "*#18*51*#1200#2*255##"
assert str(OWNEnergyCommand.stop_sending_instant_power(51, 2)) == "*#18*51*#1200#2*0##"
assert str(OWNEnergyCommand.stop_sending_instant_power("71")) == "*#18*71#0*#1200#1*0##"
Loading