Skip to content
hpbarePublic

About

No description, website, or topics provided.

Resources

Stars

0 stars

Watchers

0 watching

Forks

Latest commit

 

History

9 Commits

Folders and files

Repository files navigation

ZE07

Overview

ZE07-CO is a UART-based electrochemical carbon monoxide (CO) sensor. It supports two communication modes:

  • Initiative Upload (IU) - sensor automatically streams 1 frame/s (default mode).
  • Question and Answer (QAA) - host sends a query command, sensor replies once.

Technical Parameters

Parameter Value
Target gas CO
Interference gas Alcohol and other gases
Detection range 0~500 ppm
Resolution 0.1 ppm
Output UART (3V-TTL) / DAC (0.42V, 0full scale)
Working voltage 5V~12V (no reverse-polarity protection)
Warm-up time ≤3 min
Response time ≤60 s
Recovery time ≤60 s
Operating temperature -10°C~55°C
Operating humidity 15%RH~90%RH (no condensation)
Working life 3-5 years (in air)

Pin Description

Pin Function
1 Reserved
2 NC
3 Reserved
4 Reserved
5 GND
6 NC
7 UART RXD (0~3.0V, data input)
8 UART TXD (0~3.0V, data output)
9 Reserved
10 DAC output (0.4V2V, 0full scale)
11 NC
12 NC
13 NC
14 GND
15 Vin (5V~12V)

Communication Protocol

UART settings

Configuration Value
Baudrate 9600
Data bits 8
Stop bits 1
Parity None

UART command

All frames (commands and responses) are 9 bytes long.

Switch to QAA mode

Byte 0 Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Byte 8
0xFF 0x01 0x78 0x41 0x00 0x00 0x00 0x00 0x46

Switch to IU mode

Byte 0 Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Byte 8
0xFF 0x01 0x78 0x40 0x00 0x00 0x00 0x00 0x47

QAA query command

Host sends this frame to request one reading while in QAA mode:

Byte 0 Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Byte 8
0xFF 0x01 0x86 0x00 0x00 0x00 0x00 0x00 0x79

Response frame

IU mode (auto-streamed, 1 frame/s)

Byte Meaning
0 Start byte (0xFF)
1 Gas type (0x04 = CO)
2 Unit (0x03 = ppm)
3 No. of decimal places
4 Concentration high byte
5 Concentration low byte
6 Full range high byte
7 Full range low byte
8 Checksum

Concentration (ppm) = (byte[4] << 8 | byte[5]) * 0.1

QAA mode (response to query command)

Byte Meaning
0 Start byte (0xFF)
1 Echoed command byte (0x86)
2 Concentration high byte
3 Concentration low byte
4-7 Reserved / full-range data
8 Checksum

Concentration (ppm) = (byte[2] << 8 | byte[3]) * 0.1

Checksum

Two's-complement sum over bytes 1 to 7:

checksum = ~(byte[1] + byte[2] + ... + byte[7]) + 1

Byte 8 of every frame (command or response) must equal this value.

Cautions

  • DO NOT insert or extract the sensor on the PCB board.
  • DO NOT change or move the electronic part on the module.
  • Avoid sensor contact with organic solvent, coatings, medicine, oil and high concentration gases.
  • Excessive impact or vibration should be avoided.
  • Please keep the modules warming up for at least 5 minutes when first using.
  • Please do not use the modules in systems which related to human being’s safety.
  • Please do not use the modules in strong air convection environment.
  • Please do not expose the modules in high concentration organic gas for a long time.

About