25 changes: 25 additions & 0 deletions docs/setup/lf-setup.md
Original file line number Diff line number Diff line change
Expand Up @@ -242,6 +242,7 @@ These items can be chosen for display on the Home screen. A Nightscout Site is r

* The order in the table below is the order in the LoopFollow code
* You can drag the rows up and down to suit your preferred order
* Tap a row to open its detail, where you set its visibility and, for supported rows, [color thresholds](#color-thresholds)

| Name | Description | `Loop` / `Trio` / Both |
|:--|:--|:-:|
Expand All @@ -266,6 +267,30 @@ These items can be chosen for display on the Home screen. A Nightscout Site is r
| TDD | Total Daily Dose in the last 24 hours | `Trio` |
| IAGE | Insulin Age | Both |

#### Color Thresholds

Rows that show a single number can optionally turn **yellow** or **red** when their value crosses a threshold you set. This is a purely visual cue — it never triggers an alarm. Values that are in range stay green.

To set them up, open a row's detail from the Information Display screen, turn on **Coloring**, and set the **Yellow at** and **Red at** thresholds. Each supported row starts with sensible defaults you can adjust.

The "concerning" direction is fixed per row: battery and reservoir rows color when the value is **low**, while insulin/carb load and the age rows color when the value is **high**. *LoopFollow* keeps the Red threshold on the correct side of Yellow for that direction.

Rows that support color thresholds:

| Row | Colors when | Default Yellow / Red |
|:--|:-:|:--|
| IOB | high | 3 / 5 U |
| COB | high | 30 / 60 g |
| Battery (phone) | low | 30 / 15 % |
| Pump Battery | low | 30 / 15 % |
| Pump (reservoir) | low | 20 / 10 U |
| TDD | high | 60 / 80 U |
| Rec. Bolus | high | 1 / 2 U |
| Carbs today | high | 150 / 250 g |
| SAGE (sensor age) | high | 9 / 9.5 days |
| CAGE (cannula age) | high | 2.5 / 3 days |
| IAGE (insulin age) | high | 2.5 / 3 days |

### Units and Metrics

These settings are accessed through the *Units and Metrics* row in the Settings screen. They control how glucose is displayed throughout the app, the range used for Time in Range, and how long-term glycemic and variability metrics are reported.
Expand Down