Skip to content

feat(trace): add MH202 burglar alarm golden trace fixture and adapt profile tests (#564) - #576

Merged
GreenGrassBlueOcean merged 3 commits into
OpenWebNet-HA:v2-phase1-architecturefrom
GreenGrassBlueOcean:feat/issue-564-mh202-alarm-profile
Sep 30, 2026
Merged

GreenGrassBlueOcean merged 3 commits into
OpenWebNet-HA:v2-phase1-architecturefrom
GreenGrassBlueOcean:feat/issue-564-mh202-alarm-profile

Conversation

@GreenGrassBlueOcean

@GreenGrassBlueOcean GreenGrassBlueOcean commented Sep 30, 2026 •

Copy link
Copy Markdown
Contributor

Summary

Addresses issue #564 (remarks comment 5917195080 and comment 5917278868) by adding the on-wire MH202 burglar alarm trace as a golden fixture and adapting the topology and profile tests to OWNd's WHO 5 changes.

Companion to OpenWebNet-HA/OWNd#66. Merge this first, then OWNd#66. The tests accept both the pinned OWNd==2.0.0b9 and the #66 behaviour.

What changes for a shared bus (F454 + MH202)

 F454   WHO {..}     \
                      >--> who does each gateway own?
 MH202  WHO {..,5}   /
                                   |
                                   v
            does the MH202 uniquely carry a WHO the F454 lacks (WHO 5)?
                    |                                   |
                    | no (OWNd <= b9)                   | yes (OWNd#66)
                    v                                   v
            warm STANDBY                        SECONDARY that carries the alarm
            (repeats the primary)               (delegated WHOs now include 5,
                                                 repair copy names WHO 5)

How a WHO 5 frame reaches the panel

 WHO 5 frame on the bus
      |
      v
 WHERE starts with "#" (zone)?  --yes-->  not discovered as a panel; zone state only
      | no
      v
 WHERE == "" (empty spelling)?  --yes-->  no address, dropped (a gateway WITHOUT a
      | no                                panel dumps these on the *#5*0## poll)
      v
 alarm_control_panel at WHERE 0
      |
      v
 *5*1*0##            -> armed_away
 *5*2*0## / *5*9*0## -> disarmed
 *5*11*0##           -> armed_home on OWNd <= b9, state unchanged on OWNd#66
                        (no capture shows a system-level WHAT 11)

Changes

  1. Golden trace fixture & provenance: myhome_trace_MH202_who5_alarm_2026-09-30T18-13-13.json with 18 on-wire frames from a physical MH202 acting as a secondary next to MyHomeServer1 (contributed by @nicolacavallo84), plus a README with the capture provenance.
  2. Trace replay: tests/test_issue_564_mh202_alarm_trace.py replays all 18 frames (*5*1*0##, *5*9*0##, *5*11*#1##, *5*18*#5##) through Home Assistant and checks the panel transitions (arm away, disarm, zone status does not pollute).
  3. Topology: gateway_tier() keeps to the measured names (MH201, MH202, H4890, AM4890, LN4890). Other touch screens are unmeasured and stay tier 3, matching OWNd#66's narrowed aliases.
  4. Shared-bus tests: tests/test_multi_gateway.py and tests/test_shared_bus_onboarding.py accept the WHO 5 capability delta for F454 (primary) + MH202 (secondary) in both directions.
  5. Alarm tests: a system-level *5*11*0## accepts both armed_home (OWNd <= b9) and unchanged state (OWNd#66).
  6. Docs: README and docs/trace-availability.md trace matrix updated via scripts/sync_documentation.py; edge-case assertions adapted in tests/test_issue_466_mh200_trace.py and tests/test_message_edges.py.

Verification

Full suite passes against the local OWNd#66 checkout (2963); the alarm tests also pass against OWNd==2.0.0b9; ruff clean.

…rofile tests (OpenWebNet-HA#564)

- Add authentic MH202 on-wire burglar alarm (WHO 5) trace fixture and README documentation from community plant capture (issue OpenWebNet-HA#564 comment 5917195080)
- Add deterministic trace replay and MyHOMEAlarmControlPanel state transition tests in test_issue_564_mh202_alarm_trace.py
- Expand gateway_tier in topology.py to classify touchscreen models (HC4890, HS4890, L4890, HW4890, MH4892, MH4893, 3488, MyHomeTouch) as Tier 2
- Dynamically adapt shared-bus onboarding, delegation, and repair test assertions for MH202 when WHO 5 is supported in OWNd
- Update README.md and docs/trace-availability.md trace matrix with MH202 burglar alarm coverage
- Ensure backward/forward compatibility across parser variants in test_issue_466_mh200_trace.py and test_message_edges.py
@codecov-commenter

Copy link
Copy Markdown

⚠️ Please install the 'codecov app svg image' to ensure uploads and comments are reliably processed by Codecov.

Codecov Report

✅ All modified and coverable lines are covered by tests.

📢 Thoughts on this report? Let us know!

…et-HA#564)

OWNd narrows the H4890 profile aliases to the 3.5in 4890 family; larger
MyHome Touch and 3488 models are not measured, so they stay tier 3.

Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
@GreenGrassBlueOcean

Copy link
Copy Markdown
Contributor Author

Pushed topology.py trim: gateway_tier() is back to MH201 / MH202 / H4890 / AM4890 / LN4890, matching OWNd#66's narrowed aliases (other touch screens are unmeasured and stay tier 3).

Verified against OWNd#66 at 1445b39 (editable install): full suite 2963 passed, ruff clean.

Finding from the audit round: do not map the empty-WHERE WHO 5 spelling to 0 in OWNd. The MH200N trace in this repo (no panel) gets *5*9*## etc. as poll replies, and normalising them created a phantom alarm_control_panel.alarm_0 (test_mh200n_alarm_diagnostic_and_timed_turn_on_trace_replay failed). OWNd#66 now keeps empty as '' and only maps * to 0. Merge order stays: this PR first, then OWNd#66.

@GreenGrassBlueOcean
GreenGrassBlueOcean merged commit a645e7e into OpenWebNet-HA:v2-phase1-architecture Sep 30, 2026
16 checks passed
@GreenGrassBlueOcean
GreenGrassBlueOcean deleted the feat/issue-564-mh202-alarm-profile branch September 30, 2026 20:35
@GreenGrassBlueOcean

Copy link
Copy Markdown
Contributor Author

Pushed a test update: with OWNd#66 at e6cfe52, a system-level *5*11*0## no longer maps to armed_home (is_armed_home is always False; no capture shows it). The panel keeps its last armed state. Full suite passed against it (2962 + this fix), ruff clean.

GreenGrassBlueOcean added a commit that referenced this pull request Oct 1, 2026
…ne event (#564) (#583)

Completes the test tolerance described in item 5 of PR #576, unblocking CI conformance in OWNd#66.