Skip to content

fix(climate): align central unit mode commands and fan mode with OWNd canonical protocol (OWNd#77) - #630

Merged
GreenGrassBlueOcean merged 4 commits into
v2-phase1-architecturefrom
fix/issue-77-climate-protocol-alignment
Oct 6, 2026
Merged

GreenGrassBlueOcean merged 4 commits into
v2-phase1-architecturefrom
fix/issue-77-climate-protocol-alignment

Conversation

@GreenGrassBlueOcean

@GreenGrassBlueOcean GreenGrassBlueOcean commented Oct 5, 2026 •

Copy link
Copy Markdown
Contributor

⚠️ Release blocker

Do not merge until OWNd 2.0.0b10 is on PyPI. This PR follows the climate protocol fixes in OpenWebNet-HA/OWNd#82 (OWNd#77). Until then the jobs that install OWNd 2.0.0b9 or OWNd master (OWNd (pinned / latest / dev), HA Compatibility, test-coverage, Run Pytest Suite & Coverage) fail, because neither has the OWNd#82 frames.

Once 2.0.0b10 is published, push the prepared bump (manifest.json OWNd==2.0.0b10, pyproject.toml OWNd>=2.0.0b10, plus docs/architecture/anti-drift-safeguards.md from scripts/sync_documentation.py --update; local branch prep/ownd-2.0.0b10-bump, commit d8d5a775). CI should then go green.

Cross-repo conformance: OWNd run 37518042220 checked out OWNd 885b8e4 (the OWNd#82 head) and this PR at de8cf4b3. Both jobs passed: MyHOME suite 3476 passed, golden corpus 570 passed. The earlier run 37513598943 covered 8ed3c012.


Summary

Aligns the integration with the thermoregulation frames OWNd#82 builds. The code change is small; most of the diff updates tests that asserted the old frames.

Code (custom_components/myhome/climate.py)

  1. No fan mode on central units. #0 and #0#N have no fan coil, and OWNd#82 refuses set_fan_speed for them (the firmware drops *#4*#0*#11*S##). __init__ and _enable_fan_mode() no longer give a central unit ClimateEntityFeature.FAN_MODE or fan_modes, so a restored state can't add it back either. Turning OWNd's ValueError into a ServiceValidationError (fan_speed_zone_only) for any other caller is already on v2-phase1-architecture (fix(climate): turn OWNd's fan-speed ValueError into a service error (OWNd#77) #641).
  2. AUTO on standalone zones. Since OWNd 3014896, set_mode(CLIMATE_MODE_AUTO) always builds *4*311*#Z##. MyHOME flags every zone that is not a central unit standalone by default, so AUTO now reaches the bus for those zones instead of being dropped. The warning branch for a dropped AUTO is gone. The None check before sending stays (de8cf4b3): set_mode is still typed OWNHeatingCommand | None, and without the check mypy --strict reports an arg-type error once OWNd is importable.

Tests

  1. Central-unit modes: test_climate_central_discovery.py and test_phase2_architecture.py now expect 303 (off), 1 (heat), 0 (cool) and 311 (auto). Sources: the MyHomeServer1 firmware forwards these and drops the old 100/101/110 (own-firmware-oracle#10), and BTicino's client (libqtdevices TS10_1_0_23) sends 303/1/0 to the 99-zone central. Not verified: how a physical 3550 or 4695 central unit reacts to them.
  2. Fan speed: test_component_climate.py expects the plain zone, *#4*5*#11*S## instead of *#4*#5*#11*S##, and covers the central-unit fan guard.
  3. Golden corpus: the central-mode fixtures (*4*1*#0##, *4*0*#0##, *4*303*#0##, *4*1*#0#1##) now cite source: encyclopedia and the libqtdevices tests, as in OWNd's copy.
  4. Dry contact: test_gateway_messages.py uses WHAT 32 for the dry-contact OFF event. With 2.0.0b9, *25*0#1*31## only passed through a parser fallback that OWNd#82 fix 9 removes. WHAT 32 is the WHO 25 value, also seen in the MyHOME#418 traces.

Verification

  • Local, against OWNd 885b8e4: 3476 passed. ruff check and mypy on climate.py are clean.
  • Conformance run 37518042220, as above.

🤖 Generated with Claude Code

… canonical protocol (OWNd#77)

- Guard async_set_fan_mode against central units and catch ValueError from OWNd set_fan_speed
- Update central unit mode test assertions to match canonical WHAT codes (303 off, 1 heat, 0 cool, 311 auto)
- Update standalone zone AUTO mode test to assert gateway.send.assert_not_called()
- Update fan speed tests to expect plain zone wire frames (*#4*5*#11*1##)
- Update dry contact test to use canonical WHAT 32 for off event
- Synchronize golden thermo fixtures, corpus.json, and protocol conformance matrix
@GreenGrassBlueOcean
GreenGrassBlueOcean force-pushed the fix/issue-77-climate-protocol-alignment branch from b23cb67 to 8ed3c01 Compare October 6, 2026 18:43
OWNHeatingCommand.set_mode is typed OWNHeatingCommand | None: it still
returns None for a mode it does not build. Since OWNd#82 (3014896) AUTO is
always built as *4*311*#Z##, so the check never fires for AUTO, but sending
the result unchecked is an arg-type error under mypy --strict once OWNd is
importable (CI's ratchet runs without OWNd, which is why it passed).
Same pattern as the OFF branch above it.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
@codecov-commenter

Copy link
Copy Markdown

⚠️ Please install the 'codecov app svg image' to ensure uploads and comments are reliably processed by Codecov.

Codecov Report

✅ All modified and coverable lines are covered by tests.

📢 Thoughts on this report? Let us know!

@GreenGrassBlueOcean
GreenGrassBlueOcean merged commit 69f81dc into v2-phase1-architecture Oct 6, 2026
17 checks passed
@GreenGrassBlueOcean