Summary

Prepares MyHOME for OpenWebNet-HA/OWNd#82 (the OWNd#77 firmware findings). With that PR, OWNHeatingCommand.set_fan_speed raises ValueError for a central unit (#0, #0#N) or the general zone. The firmware forwards *#4*Z*#11*S## only for a plain zone 1–99 (gdluck's audit A2; *#4*#0*#11*1## produces no bus frame). async_set_fan_mode did not catch it, so the service call failed with an unhandled error.

async_set_fan_mode now turns it into a ServiceValidationError (fan_speed_zone_only, translated in en/fr/it/nl). It sends nothing and leaves the fan mode as it was. A central entity can expose a fan mode when a restored state had one (async_restore_last_state).

The test patches the OWNd builder, so it passes with the pinned OWNd 2.0.0b9 and with the OWNd#82 head.

The other downstream item from the review, AUTO on zones flagged standalone, is handled in OWNd#82: set_mode(AUTO) now always builds *4*311*#Z##, so MyHOME needs no change for it. (Every zone that is not a central unit defaults to standalone=True here, so hiding AUTO for standalone zones would have removed it from zones that do run under a central unit.)

Not in this PR

The OWNd bump itself. With the OWNd#82 head, these tests still assert the old frames and must be updated when OWNd is bumped: test_climate_central_discovery.py, test_component_climate.py (2), test_gateway_messages.py::TestDryContactEvents::test_dry_contact_off, test_golden_conformance.py (four central-mode builder-parity cases), test_heating.py::test_set_fan_speed_variations, test_phase2_architecture.py (2).

Verification

  • New test: 2 passed with OWNd 2.0.0b9 (the pinned release) and with the OWNd#82 head.
  • Full suite with OWNd 2.0.0b9: 3414 passed, 9 skipped, 3 failed. The 3 failures (test_component_alarm.py::test_alarm_setup_restores_and_discovers, test_issue_619_dimmer_trace.py::test_f453av_sweep_trace_replay, test_issue_629_f454_central_unit_trace.py::test_f454_sweep_trace_replay) also fail on v2-phase1-architecture @ 0f7b0de with b9, so this PR does not cause them.
  • Full suite with an OWNd#82 checkout: only the 11 old-frame tests listed above fail.
  • ruff check, scripts/verify_ha_standards.py and scripts/sync_documentation.py --check are clean.

🤖 Generated with Claude Code

…OWNd#77)

OWNd#82 makes OWNHeatingCommand.set_fan_speed raise ValueError for a
central unit or the general zone: the firmware forwards *#4*Z*#11*S## only
for a plain zone 1..99 (gdluck's audit A2). async_set_fan_mode did not catch
it. It now raises ServiceValidationError (fan_speed_zone_only, en/fr/it/nl),
sends nothing and keeps the fan mode. The test patches the builder, so it
passes with OWNd 2.0.0b9 and with the OWNd#82 head.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
@codecov-commenter

Copy link
Copy Markdown

⚠️ Please install the 'codecov app svg image' to ensure uploads and comments are reliably processed by Codecov.

Codecov Report

✅ All modified and coverable lines are covered by tests.

📢 Thoughts on this report? Let us know!

@GreenGrassBlueOcean
GreenGrassBlueOcean merged commit a0890e3 into v2-phase1-architecture Oct 6, 2026
17 checks passed
@GreenGrassBlueOcean
GreenGrassBlueOcean deleted the fix/ownd77-climate-guards branch October 6, 2026 18:21
xtimmy86x pushed a commit to xtimmy86x/MyHOME that referenced this pull request Oct 8, 2026